Showing results: 46 - 60 of 159 items found.
-
La Marche Manufacturing Company
This patented battery tester has the capability to store battery discharge curve as a benchmark to analyze battery health trends.
-
17040 -
Chroma Systems Solutions, Inc.
The 17040 Regenerative Battery Pack Test System is a high precision system specifically designed for secondary battery module and battery pack test. It has an energy regenerative function to greatly reduce power consumption during discharge, and ensure a stable power grid without generating harmonic pollution on other devices – even in dynamic charge and discharge conditions. It is capable of recycling the energy discharged by the battery pack test back to the grid reducing wasted energy that traditional equipment discharges in the form of heat.
-
PRODIGIT Electronics Co, Ltd.
*Easy to see now test progress*Can cycle test*Provide Charge, Discharge, Suspend, FOR, LOOP Mode Select*When Charging, set the stop current to stop charging when fully charged so as to avoid overcharging that will damage the battery. When Discharge, set the stop voltage to stop discharge when discharging to lowest so as to avoid over-discharging that will damage the battery.
-
BD12-110P -
Manatronics Pty Ltd
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with 110V battery systems and is extremely costeffective.
-
BD12-110P-48/24 -
Manatronics Pty Ltd
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with 110V battery systems and is extremely costeffective.
-
KVBT-15S -
KV Hipot Power Test Equipment Co.,Ltd
Battery Internal Resistance Tester with advanced AC discharge measurement method, is applied to test accurately the voltage and resistance of battery capacity and state.
-
MH-C9000 -
Maha Energy Corporation
It's like having four charger-analyzers for AA and AAA NiMH / NiCD batteries. Refresh & Analyze: Charges the battery, rest for one hour, discharge, rest again, then recharges it. Selectable charging and discharging rate. Break-In: Also known as IEC capacity measurement and "Battery Forming". Charges battery at 0.1C for 16 hours, rest for one hour, discharges battery at 0.2C, then recharges again at 0.1C for 16 hours.
-
BD12-24P-12 -
Manatronics Pty Ltd
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with 24V battery systems and is extremely cost effective.
-
IBEKO Power AB
Performing capacity/discharge test on a high-capacity battery may be challenging since high requirements are set on the discharge system. In cases when discharge test times need to be reduced, high load capacities are required from the discharge system. The battery extra load unit BXL is an additional load unit designed especially for this purpose.It is primarily used with BLU battery testers. However, the unit is a universal add-on device. This means it can be used as an additional load with any other discharge/capacity tester in the market.When discharge current exceeds the capacity of a single BLU device, extra load unit increases discharge capacity. A system of BLU and BXL instruments enables performing the capacity test in an accurate, user-friendly way in accordance to battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.
-
-
ELAK Private Ltd.
ELAK Battery Testers are high-rate discharge testers. These testers impose a load on the battery, which is equivalent to that drawn by the starter motor from the battery, while cranking the engine. The tester studies the drop in battery voltage & indicates the condition of the battery if it is capable of starting the engine or not.
-
BD12-48P-24/12 -
Manatronics Pty Ltd
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with 12V, 24V and 48V Battery systems and isextremely cost effective.
-
BD18-48P-24/12 -
Manatronics Pty Ltd
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with 12V, 24V and 48V Battery systems and isextremely cost effective.
-
BD15-48P-24/12 -
Manatronics Pty Ltd
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with 12V, 24V and 48V Battery systems and is extremely cost effective.
-
K-3980 -
Kongter Test & Measurement Co., Limited
Kongter offers a series of customized DC load banks with many different models for constant current battery discharge test and battery capacity test. They cover a wide voltage range from 12V to 480V nominal voltages with current up to 600A. They are widely applied in various industries. With its optional battery Data Acquisition Case (DAC), discharge values of EACH cell could be monitored in battery load bank and PC software simultaneously by using Kongter’s data view software.